LeafNLP Demos
Back to explore

Report #2868750

Received Oct 27, 2025

Reports are unverified and do not show that a vaccine caused an event. Full disclaimer

Overview

Sex
Male
Age
23 yrs
State
CA
Recovered
Unknown
Vaccinated
Oct 24, 2025
Onset
Oct 24, 2025
Days to onset
0
Hospital days
—

Vaccines (1)

TypeNameManufacturerDoseLotRoute / Site
COVID19COVID19 (COVID19 (MODERNA))MODERNAN/A3052550IM / LA

Symptoms (1)

Product preparation error

Symptom narrative

Timeline of Events 5:11 PM ? Employee removed two boxes of Moderna Spikevax prefilled syringes from frozen storage (-15°C to -50°C) and placed them into the refrigerator (2°C?8°C) for thawing. She labeled the boxes with an incorrect ?ready-to-use? time of 5:51 PM (40 minutes after removal). Per the XO COVID-19 Vaccine Reference Guide, thawing in the refrigerator requires 2 hours and 40 minutes for a carton of 10 syringes. Therefore, the correct ?ready-to-use? time should have been 7:51 PM. 5:55 PM ? The Moderna Spikevax dose was administered to the patient by employee, approximately 44 minutes after being placed in the refrigerator (well before the required thaw period). During administration: employee met injection resistance and could not fully discharge the syringe. Upon withdrawing the syringe, she noted that the vaccine appeared partially frozen (approximately 1 inch of frozen content remaining). Some vaccine liquid came into contact with her finger during inspection. 6:05 PM ? Employee reported the incident to the MA Lead. Employee, who had assisted in preparing the vaccines (Flu, COVID-19, and HPV #1), confirmed she and employee had verified the syringes together prior to administration. Deviation from Manufacturer and CDC Protocol According to Moderna and CDC storage and handling guidance: A prefilled Spikevax syringe requires at least 1 hour and 40 minutes to thaw in the refrigerator (2°C?8°C) before administration. The administered dose was thawed for only 44 minutes, meaning it was not fully thawed and therefore administered outside of manufacturer protocol. This constitutes a handling deviation.